Skip to main content
  • Italiano
  • Italiano

TWIN WALL: PAINTED FLUE SYSTEM DWCo25

Twin wall flue system in stainless steel internal AISI 316L painted external - rock wool insulation 25 mm thick

The DWC25 twin wall flue system is made up of rigid modular components with a painted finish, manufactured with an internal wall in AISI 316L stainless steel with a minimum thickness of 0.4 mm and an external wall in painted steel with a thickness of 0.5 mm, compliant with the required CE marking according to the EN 1856/1 European standard. The insulation is made of 25 mm thick high-density rockwool, inserted between the walls without joining components between them (thermal bridge). The modular components have a classic male-female socket coupling calibrated for both walls with a triple lip seal to be inserted on the internal wall, compliant with European standard EN 14241-1, and a mechanical joint with a safety clamp.

ON REQUEST

DESIGNATIONS OF USE

Click on the designation to find out the related usage specifications
Designation T200 H1 W V2 L50040 O30 (resistance up to 5000 Pa with seal)
CONDENSATION RESISTANT

YES

INTERNAL WALL
AISI 316L
OUTER WALL

Painted

INSULATION

Rock wool

INSULATION THICKNESS

25 mm

DIAMETERS

⌀ 80 ÷ 300

TEMPERATURE LEVEL
200 °C  
PRESSURE LEVEL
H1 = 5000 Pa
GAS APPLIANCES
RECOMMENDED
GAS CONDENSING APPLIANCES
RECOMMENDED
OIL APPLIANCES
RECOMMENDED
WOOD-BURNING APPLIANCES
NO
PELLET APPLIANCES
RECOMMENDED
GAS COOKER HOODS
POSSIBLE
VENTILATION
POSSIBLE
OUTDOOR INSTALLATION
RECOMMENDED
INDOOR INSTALLATION
RECOMMENDED
INSTALLATION IN CAVITY
POSSIBLE
Designation T200 P1 W V2 L50040 O30 (resistance up to 200 Pa with seal)
CONDENSATION RESISTANT

YES

INTERNAL WALL
AISI 316L
OUTER WALL

Painted

INSULATION

Rock wool

THICKNESS

25 mm

DIAMETERS

⌀ 80 ÷ 500

TEMPERATURE LEVEL
200 °C
PRESSURE LEVEL
P1 = 200 Pa
GAS APPLIANCES
RECOMMENDED
GAS CONDENSING APPLIANCES
RECOMMENDED
OIL APPLIANCES
RECOMMENDED
WOOD-BURNING APPLIANCES
NO
PELLET APPLIANCES
RECOMMENDED
GAS COOKER HOODS
POSSIBLE
VENTILATION
POSSIBLE
OUTDOOR INSTALLATION
RECOMMENDED
INDOOR INSTALLATION
RECOMMENDED
INSTALLATION IN CAVITY
POSSIBLE
Designation T600 N1 W V2 L50040 050 G70 (vacuum chimney system)
CONDENSATION RESISTANT

YES

INTERNAL WALL
AISI 316L
OUTER WALL

Painted

INSULATION

Rock wool

INSULATION THICKNESS

25 mm

DIAMETERS

⌀ 80 ÷ 800

TEMPERATURE LEVEL
600 °C
PRESSURE LEVEL
N1 = 40 Pa
GAS APPLIANCES
RECOMMENDED
GAS CONDENSING APPLIANCES
RECOMMENDED
AOIL APPLIANCES
RECOMMENDED
WOOD-BURNING APPLIANCES
RECOMMENDED
PELLET APPLIANCES
RECOMMENDED
GAS COOKER HOODS
POSSIBLE
VENTILATION
POSSIBLE
OUTDOOR INSTALLATION
RECOMMENDED
INDOOR INSTALLATION
RECOMMENDED
INSTALLATION IN CAVITY
POSSIBLE

Request information