TWIN WALL: DW25R COPPER
Twin wall flue system in stainless steel internal AISI 316L copper external - rockwool insulation 25 mm thick
The DWC25 twin wall flue system is made up of rigid modular elements with a copper finish, manufactured with an internal wall in AISI 316L stainless steel with a minimum thickness of 0.4 mm and an external wall in natural copper with a thickness of 0.5 mm, compliant with CE marking according to EN 1856/1 European standards. Insulation is 25 mm thick high-density rockwool, inserted between the walls without joining elements between them (thermal bridge). The modular elements have a classic male-female socket coupling calibrated for both walls with a triple lip seal to be inserted on the internal wall, and a mechanical joint with a saftey clamp. All compliant with European standard EN 14241-1.
ON REQUEST
DESIGNATIONS OF USE
CONDENSATION RESISTANT
|
YES |
|
INTERNAL WALL
|
AISI 316L | |
OUTER WALL
|
Copper |
|
INSULATION
|
Rock wool |
|
INSULATION THICKNESS
|
25 mm |
|
DIAMETERS
|
⌀ 80 ÷ 300 |
|
TEMPERATURE LEVEL
|
200 °C
|
|
PRESSURE LEVEL
|
H1 = 5000 Pa
|
|
![]() |
GAS APPLIANCES
|
RECOMMENDED
|
![]() |
GAS CONDENSING APPLIANCES
|
RECOMMENDED
|
![]() |
OIL APPLIANCES
|
RECOMMENDED
|
![]() |
WOOD-BURNING APPLIANCES
|
NO
|
![]() |
PELLET APPLIANCES
|
RECOMMENDED
|
![]() |
GAS COOKER HOODS
|
RECOMMENDED
|
![]() |
VENTILATION
|
POSSIBLE
|
![]() |
OUTDOOR INSTALLATION
|
RECOMMENDED
|
![]() |
INDOOR INSTALLATION
|
RECOMMENDED
|
![]() |
INSTALLATION IN CAVITY
|
POSSIBLE
|
CONDENSATION RESISTANT
|
YES |
|
INTERNAL WALL
|
AISI 316L | |
OUTER WALL
|
Copper |
|
INSULATION
|
Rock wool |
|
INSULATION THICKNESS
|
25 mm |
|
DIAMETERS
|
⌀ 80 ÷ 500 |
|
TEMPERATURE LEVEL
|
200 °C
|
|
PRESSURE LEVEL
|
P1 = 200 Pa
|
|
![]() |
GAS APPLIANCES
|
RECOMMENDED
|
![]() |
GAS APPLIANCES
|
RECOMMENDED
|
![]() |
OIL APPLIANCES
|
RECOMMENDED
|
![]() |
WOOD-BURNING APPLIANCES
|
NO
|
![]() |
PELLET APPLIANCES
|
RECOMMENDED
|
![]() |
GAS COOKER HOODS
|
POSSIBLE
|
![]() |
VENTILATION
|
POSSIBLE
|
![]() |
OUTDOOR INSTALLATION
|
RECOMMENDED
|
![]() |
INDOOR INSTALLATION
|
RECOMMENDED
|
![]() |
INSTALLATION IN CAVITY
|
POSSIBLE
|
CONDENSATION RESISTANT
|
YES |
|
INTERNAL WALL
|
AISI 316L | |
OUTER WALL
|
Copper |
|
INSULATION
|
Rock wool |
|
INSULATION THICKNESS
|
25 mm |
|
DIAMETERS
|
⌀ 80 ÷ 800 |
|
TEMPERATURE LEVEL
|
600 °C
|
|
PRESSURE LEVEL
|
N1 = 40 Pa
|
|
![]() |
GAS APPLIANCES
|
RECOMMENDED
|
![]() |
GAS CONDENSING APPLIANCES
|
RECOMMENDED
|
![]() |
OIL APPLIANCES
|
RECOMMENDED
|
![]() |
WOOD-BURNING APPLIANCES
|
RECOMMENDED
|
![]() |
PELLET APPLIANCES
|
RECOMMENDEDO
|
![]() |
CAPPE CUCINA A GAS
|
POSSIBGAS COOKER HOODSLE
|
![]() |
VENTILATION
|
POSSIBLE
|
![]() |
OUTDOOR INSTALLATION
|
RECOMMENDED
|
![]() |
INDOOR INSTALLATION
|
RECOMMENDED
|
![]() |
INSTALLATION IN CAVITY
|
POSSIBLE
|